Aitech CM950

Radiation Tolerant PMC Carrier Card

Manufacturer: Aitech
Aitech CM950
Introduction

The CM950 transition module provides standard direct connection to I/O interfaces on the S950 and the hosted PMC module and is intended for use in commercial 3U cPCI air-cooled chassis. It eliminates the need for any harnessing and complex cabling fixtures in order to connect to the SBC and the I/Os based on the PMC module used with the S950 in a single slot solution.

Designed for harsh space environment applications, the CM951 flight model has an unshielded total dose capacity of 45 krad (Si). An optional 100 krad version is available upon request.

ADAPTER/CARRIER

FeaturesLess than 2W Power Consumption
Design for Use with Multiple S950 SBCs and Conduction-Cooled PMCs in an Enclosure
Radiation Tolerant PCI-PCI Bridge Design for use in Rugged Space Application
Accommodate a Single-Wide Conduction-Cooled PMC
Design in Single-Slot 3U CompactPCI (cPCI) Form Factor
Support PCI Bus Specification 2.3 and PCI Bridge Specification 1.1
Support for Full Arbitration of PMC Master Operations
PMC I/O routed to cPCI J2 Connector for Backplane Routing
Both Engineering Model and Flight Model are available in Conduction-Cooled format per VITA 30.1-2002 Specification
Optional Radiation Hardened Version is Available Upon Request
ConnectionsAccommodate a Single-Wide Conduction-Cooled PMC

 

GENERAL

ExpansionSupport PCI Bus Specification 2.3 and PCI Bridge Specification 1.1
One standard PMC slot
Electrical2W maximum – 1.5W on 5Vdc and 0.5W on 3.3Vdc
MechanicalBoth Engineering Model and Flight Model are available in Conduction-Cooled format per VITA 30.1-2002 Specification
Conformal CoatingConformal optional (series 100), standard (series 200/500). Acrylic or Silicone
TemperatureSeries-100 Lab Grade EDU
• Temperature range (operation): 0 to +55°C
• Temperature range (storage): -40 to +85°C

Series-200 Qual Unit
• Temperature range (operation): -40 to +71°C
• Temperature range (storage): -50 to +100°C

Series-500 Radiation Tolerant Flight Unit
• Temperature range (operation): -40 to +65°C (space vacuum)
• Temperature range (storage): -62 to +125°C

Ruggedisation level is determined in the part numbering scheme - refer to datasheet for further details
HumiditySeries-100 Lab Grade EDU: 0-90%
Series-200 Qual Unit: 0-100% (coating as standard)
Series-500 Radiation Tolerant Flight Unit: 0-100% (coating as standard)
AltitudeSeries-100 Lab Grade EDU: 15,000ft
Series-200 Qual Unit: 70,000ft
Series-500 Radiation Tolerant Flight Unit: 10 to the -4 Torr
VibrationSeries-100 Lab Grade EDU:
• Random (g2/Hz): 20-2000Hz/0.02 g2/Hz
• Sine (g PEAK): 10-100Hz/2g

Series-200 Qual Unit:
• Random (g2/Hz): 20-2000Hz/0.1 g2/Hz
• Sine (g PEAK): 50-500Hz/10g

Series-500 Radiation Tolerant Flight Unit:
• Conduction-cooled: Random (g2/Hz): 20-2000Hz/0.1 g2/Hz
• Conduction-cooled: Sine (g PEAK): 50-500Hz/10g
ShockSeries-100 Lab Grade EDU: 20g/6mS
Series-200 Qual Unit: 40g/11ms, 100g/6ms
Series-500 Radiation Tolerant Flight Unit: 40g/11ms, 100g/6ms (pyro-shock 875g)
Warranty1 Year
RoHSCompliant

ORDERING DETAILS

BoardRefer to datasheet for ordering part number scheme
AccessoriesN/A
Recab UK
Interested in this Product?

Get In Touch