GENERAL |
Expansion | OpenVPX (VITA 65) Slot Profiles: • SLT3-PAY-2F2U (supported by standard configurations of the C912). Payload board, Two Fat Pipes (Factory Configured as PCIe or 10G XAUI), Two Ultra-Thin Pipes (1000Base-BX/KX) • SLT3-PAY-2F2T (available as a special order option, contact your Aitech representative for more information). Payload board, Two Fat Pipes (Factory Configured as PCIe or 10G XAUI), Two Thin Pipes (1000Base-T)
Backplane PCIe interfaces are configured as two x4 ports by default. Additional port configurations (up to 8 ports) are available by factory configuration of the PCIe switch firmware, contact your Aitech representative for more information.
XMC slot: PCIe x4 interface supporting Gen2 and Gen1 speeds and port widths of x4/x2/x1, 5 V VPWR supply |
Electrical | The C112 is designed to take its main power from 5V (VS3) or 12 V (VS1 + VS2). When working from 12V, the C112 still draws 2 A from the 5 V supply. When the C112 takes its main power from 5 V, no 12 V supply is required. |
Mechanical | Air-cooled: 3U VPX REDI per ANSI/VITA 48.1, 1 inch pitch Conduction-cooled: 3U VPX REDI per ANSI/VITA 48.2, 0.8 inch pitch Conduction-cooled 2LM: 3U VPX REDI 2LM (Two Level Maintenance) per ANSI/VITA 48.2, 0.85 inch pitch All mechanical formats are single slot 3U modules |
Conformal Coating | Acrylic (Silicone and Urethane Optional) |
Software | Wind River VxWorks®, Linux®, and Green Hills INTEGRITY® are supported |
Temperature | Air-Cooled Commercial • Temperature range (operation): 0 to +55C • Temperature range (storage): -40 to +85C
Air-Cooled Rugged • Temperature range (operation): -40 to +70C • Temperature range (storage): -50 to +100C
Air-Cooled Military • Temperature range (operation): -40 to +85C • Temperature range (storage): -55 to +125C
Conduction-Cooled Rugged • Temperature range (operation): -40 to +70C • Temperature range (storage): -50 to +100C
Conduction-Cooled Military • Temperature range (operation): -40 to +85C • Temperature range (storage): -55 to +125C |
Humidity | Air-Cooled Commercial: 0-90% All others: 0 to 100% with coating |
Weight | Air-cooled: < 400 g (0.88 lbs.) – Commercial version, < 700 g (1.55 lbs.) – Rugged and Military versions Conduction-cooled: < 780 g (1.72 lbs.) Conduction-cooled 2LM: < 860 g (1.90 lbs.) |
Altitude | Air-Cooled Commercial: 15,000 ft. Air-Cooled Rugged: 35,000 ft. Air-Cooled Military: 70,000 ft. Conduction-Cooled Rugged: 35,000 ft. Conduction-Cooled Military: 70,000 ft. |
Vibration | Specs per VITA 47: Air-Cooled Commercial: V1 Air-Cooled Rugged: V2 Air-Cooled Military: V2 Conduction-Cooled Rugged: V3 Conduction-Cooled Military: V3 |
Shock | Specs per VITA 47: Air-Cooled Commercial: OS1 Air-Cooled Rugged: OS1 Air-Cooled Military: OS1 Conduction-Cooled Rugged: OS2 Conduction-Cooled Military: OS2 |
Warranty | 1 Year |
RoHS | Compliant |